SCG-1 User Manual Warning! The Oxygen Sensor used in this device gets very hot in operation. Do not touch a hot sensor. Do not let a hot sen
10 Race Application - Calibrate before first installation of new sensor - Calibrate once per race weekend 3 Boost Controller Setup 3.1 Entering Se
11 Once you have completed your desired changes, press the Program button on the lower right on the software application. You will know that the SCG-
12 Tuning Tip: Start small and work up. Do not increase Wastegate Duty if Boost/AFR cuts occur. Remedy Boost/AFR cuts before increasing Wastegate Dut
13 defined lean A/F that will trigger the safety cut. When the Boost Cut by AFR is triggered, the SCG-1 will display “O2 Cut” on the upper right han
14 4. The installer will start, follow the prompts to install the software. 5. Once the software has been installed, the LogWorks software, LM Pr
15 By selecting the ‘use Air-Fuel-Ratio’ button you can change the displayed unit of measure for mixture by AFR instead of Lambda. This does not cha
16 1. Connect the SCG-1 to the computer and launch LM Programmer. 2. Once connected, LM Programmer will display the current version of the firmwa
17 Appendix A: Limited Warranty LIMITED WARRANTY Innovate stands behind the quality of its products. Innovate makes the following warran
18 MERCHANTABILITY, NONINFRINGEMENT, AND FITNESS FOR A PARTICULAR PURPOSE, AND THE LIABILITY OF INNOVATE, IF ANY, FOR DAMAGES RELATING TO ANY ALLEGED
19 4. Replace sensor. Error 9 Supply Voltage too low Supply voltage too low for sensor regulation 1. Verify you have 12V at your power source and the
2 1 SCG-1 The SCG-1 is a boost solenoid controller gauge with an integrated wideband AFR (lambda) control. The SCG-1 also has advanced safety boo
3 3. Interface Buttons - Pressing either the left or right interface buttons will allow you to cycle through the 4 different display modes. - F
4 3. Configure the gauge as desired by changing the gauge face and/or bezel. 4. Make sure every piece is positioned correctly using the locati
5 3 Connect the WHITE wire to a headlight power wire (a wire that goes hot with 12V when the headlights are on)). This enables the display to dim for
6 2.2 Gauge Mounting and Routing The SCG-1 gauge fits in any standard 2 1/16” (52mm) gauge pod. Mounting of the gauge should be done in such a mann
7 2.3.2 External Wastegate 2.4 MAP sensor 1. The MAP sensor MUST be installed with the hose fitting facing down. It is very important that the se
8 accurate readings. Using a bung is the preferred method for mounting the oxygen sensor in all applications. - Weld the bung at least 24 inches a
9 2.5.2 Sensor Calibration Once the unit has been wired and a suitable location has been found for both the gauge and the sensor. it is time to perfo
Commentaires sur ces manuels