Innovate-motorsports LMA-3 Manuel d'utilisateur Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
- 4 -
Each of the five inputs of the LMA-3 can be user configured for different functionalities.
The 7-segment display of the LMA-3 (Function indicator) will show which functionality is selected.
The following tables show the functionality of each of the 5 inputs of the LMA-3:
Input 1 Functions
Function
Indicator
1 2 =
Functionality RPM
(0..10230)
RPM
(0..20460)
External 0..5V
sensors
Input 2 Functions
Function
Indicator
1 2 3 4 5 =
Functionality Thermocouple
EGT range
(0..1093 degC,
32..1999 degF)
Thermocouple
CHT range
(0..300 degC,
32..572 degF)
Side
Force
(+- 2g )
Side
Force
(+- 1g)
Side
Force
(+- 0.25g)
External 0..5V
sensors
Input 3 Functions
Function
Indicator
1 2 F =
Functionality Duty Cycle N/A Frequency
(straight
frequency,
Speed sensor,
Custom RPM
range
External 0..5V
sensors
Input 4 Functions
Function
Indicator
1 2 3 4 F d =
Functionality MAP (1
bar)
(0..101.3
kPa)
MAP (3
bar)
(0..304.1
kPa)
Vaccuum
(0..30
inHg
Vacc)
Vaccum/Boost
(-14.7PSI…
29.4 PSI)
Frequency
(straight
frequency,
Speed
sensor,
Custom
RPM range
Duty
Cycle
External
0..5V
sensors
Vue de la page 3
1 2 3 4 5 6 7 8 9 ... 29 30

Commentaires sur ces manuels